IOL Power (SRK II)

Intraocular-lens power by the SRK II regression formula with the axial-length adjustment band (Sanders / Retzlaff / Kraff 1988).

Open the calculator → Runs in your browser. Data leaves only if you deliberately send a problem report from the interactive tool.

Example

Lens A-constant
118.4
Axial length
23.5 mm
Average keratometry
44 D
Target refraction
0 D

Result: Emmetropic IOL power 20.05 D for AL 23.5 mm (A-constant adjustment 0).

The tool opens with these values already filled in. Replace them with your own.

What the result means

Caveat
A regression formula superseded by optical/theoretical formulas (SRK/T, Barrett); does not replace device biometry. Target refraction applies the SRK refractive factor ≈ 1.25 D/D.

What you enter

  • Lens A-constant
  • Axial length
  • Average keratometry
  • Target refraction (0 for emmetropia)
How this is calculated
Formula
P = A1 − 0.9·K − 2.5·AL; A1 = A-constant adjusted for axial length (AL<20 +3, 20–21 +2, 21–22 +1, 22–24.5 0, ≥24.5 −0.5).

Sanders DR, Retzlaff J, Kraff MC. Comparison of the SRK II formula and other second-generation formulas. J Cataract Refract Surg. 1988;14(2):136-141. Read the source ↗

A reference and educational tool. Not medical, legal, or financial advice, and not a substitute for clinician judgment.