CGM Time in Range Targets (International Consensus)
Checks the five CGM report percentages against the International Consensus time-in-range targets.
Open the calculator → Runs in your browser. Data leaves only if you deliberately send a problem report from the interactive tool.
Example
- Population
- Type 1 or type 2 diabetes
- Time below 54 mg/dL
- 0.5 %
- Time from 54 to 69 mg/dL
- 2.5 %
- Time from 70 to 180 mg/dL
- 68 %
- Time from 181 to 250 mg/dL
- 22 %
- Time above 250 mg/dL
- 7 %
Result: 2 of 5 consensus targets met (type 1 or type 2 diabetes): time in range (70 to 180 mg/dL) 68% against a target above 70%; time above 180 mg/dL 29% against a target below 25%; time above 250 mg/dL 7% against a target below 5%.
The tool opens with these values already filled in. Replace them with your own.
What you enter
- Population
- Time below 54 mg/dL
- Time from 54 to 69 mg/dL
- Time from 70 to 180 mg/dL
- Time from 181 to 250 mg/dL
- Time above 250 mg/dL
- Glucose variability (%CV)
- Days worn
- Time the CGM was active
How this is calculated
Citation
Battelino T, Danne T, Bergenstal RM, et al. Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range. Diabetes Care. 2019;42(8):1593-1603. Read the source ↗
A reference and educational tool. Not medical, legal, or financial advice, and not a substitute for clinician judgment.